H1z2z2-K PV Solar Cable Copper XLPE Insulation DC PV Solar Wire Cable 2.5mm 4mm 6mm 10mm 16mm2
Transactions: US$10,000+
Contact Supplier
Still deciding? Get samples of $ !
Request Sample
Product Highlights
- 30-Year Lifespan: Durable design lasts up to 30 years even under tough conditions.
- Halogen-Free Safety: Low smoke emission and low toxicity during fire with non-toxic materials.
- UV and Weather Resistance: Excellent resistance to UV, water, oxygen, oil, chemicals, and ozone.
- Dual Wall Protection: Impact, tear, and abrasion resistant with dual wall insulation.
- TUV Certification: Approved by TUV standards for quality and safety assurance.
- Flexible Installation: Excellent flexibility and stripability for fast and easy installation.
- Pure Copper Conductor: Made with tinned pure copper wire for optimal conductivity.
Product Attributes
- Customization
- Available
- Type
- Solar Cable
- Conductor Type
- Pure Copper
- Model NO.
- H1Z2Z2-K
- Application
- Heating, Other
- Conductor Material
- Copper
- Sheath Material
- PVC
- Insulation Material
- PVC
- Material Shape
- Round Wire
- Range of Application
- Other
- Certification
- CE, RoHS
- Brand
- Summao
- Transport Package
- Neutral Packaging
- Specification
- 0.25 4 6 10 16 25 35
- Trademark
- summao
- Origin
- Guangdong
- Production Capacity
- 100000/Week
- Package Size
- 30.00cm * 30.00cm * 30.00cm
- Package Gross Weight
- 10.500kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of H1z2z2-K PV Solar Cable Copper XLPE Insulation DC PV Solar Wire Cable 2.5mm 4mm 6mm 10mm 16mm2
Find Similar Products
Product Description
Product features
Low smoke without halogen, good cold, ultraviolet, ozone - resistant and weather - resistant.
Flame retardant, cutting resistance and penetration resistance.
Cable protection level level.
With 150 ºC photovoltaic cable radiation as insulation materials, halogen free flame retardant is halogen-free, non-toxic modified polyethylene thin hengjing resin as the main raw material, add halogen-free, non-toxic, flame retardant, heat stabilizer, eliminate smoke agent, preservative, such as fertilizer, does not contain halogen, heavy metals, phosphorus.
It conforms to ROHS, and the insulation resistance is small after immersion.
Electrical
1. The dc resistance: the finished cable at 20 ºC conductive wire core dc resistance is not greater than 5.09 Ω/km
2. The insulation resistance: the finished insulation resistance of cable at 20 ºC should not less than 1014 Ω. Cm, finished cable insulation resistance at 90 ºC is not less than 1011 Ω. Cm
3. The sheath surface resistance: resistance of the finished cable sheath surface should be not less than 109 Ω.
Cable structure
Conductor: tinned copper wire 2.5, 4, 6, 10, 16 mm² 2 PV1 - F
18, 16 and 14, 12, 10, 8, 6, 4, 2 mm² PV wire
Insulation: > 0.5mm thick with low smoke and halogen material, and meet the specified limit of the customer.
Sheath: low smoke and halogen free material thickness > 0.5mm.
parameters
Ambient temperature: - 40 ºC ~ + 90 ºC
The highest temperature of conductor: 120 ºC (allow 5 s in short circuit temperature 200 ºC)
Limited voltage: AC0.6/1kv dc1.8kv.
Low smoke without halogen, good cold, ultraviolet, ozone - resistant and weather - resistant.
Flame retardant, cutting resistance and penetration resistance.
Cable protection level level.
With 150 ºC photovoltaic cable radiation as insulation materials, halogen free flame retardant is halogen-free, non-toxic modified polyethylene thin hengjing resin as the main raw material, add halogen-free, non-toxic, flame retardant, heat stabilizer, eliminate smoke agent, preservative, such as fertilizer, does not contain halogen, heavy metals, phosphorus.
It conforms to ROHS, and the insulation resistance is small after immersion.
Electrical
1. The dc resistance: the finished cable at 20 ºC conductive wire core dc resistance is not greater than 5.09 Ω/km
2. The insulation resistance: the finished insulation resistance of cable at 20 ºC should not less than 1014 Ω. Cm, finished cable insulation resistance at 90 ºC is not less than 1011 Ω. Cm
3. The sheath surface resistance: resistance of the finished cable sheath surface should be not less than 109 Ω.
Cable structure
Conductor: tinned copper wire 2.5, 4, 6, 10, 16 mm² 2 PV1 - F
18, 16 and 14, 12, 10, 8, 6, 4, 2 mm² PV wire
Insulation: > 0.5mm thick with low smoke and halogen material, and meet the specified limit of the customer.
Sheath: low smoke and halogen free material thickness > 0.5mm.
parameters
Ambient temperature: - 40 ºC ~ + 90 ºC
The highest temperature of conductor: 120 ºC (allow 5 s in short circuit temperature 200 ºC)
Limited voltage: AC0.6/1kv dc1.8kv.
| TYPE | Conductor diameter | Conductor diameter | Outer diameter | Conductor resistance | Rated current | Rated current | Rated current |
| 1x2.5mm² | 2.5mm² | 48x0.25 | 2.0 | 5.2 | 8.06 | 1000/1800 | 30 |
| 1x4.0mm² | 4.0mm² | 56x0.30 | 2.6 | 6.4 | 4.97 | 1000/1800 | 50 |
| 1x6.0mm² | 6.0mm² | 81x0.30 | 3.3 | 7.2 | 3.52 | 1000/1800 | 70 |
| 1x10mm² | 10mm² | 74x0.40 | 4.4 | 8.3 | 2.12 | 1000/1800 | 95 |
| 2x2.5mm² | 2.5mm² | 48x0.25 | 2.0 | 6.2x9.9 | 8.06 | 1000/1800 | 30 |
| 2x4.0mm² | 4.0mm² | 56x0.30 | 2.6 | 6.9x11.30 | 4.79 | 1000/1800 | 50 |
| 2x6.0mm² | 6.0mm² | 81x0.30 | 3.3 | 7.1x14.50 | 3.52 | 1000/1800 | 70 |